Peppers cable gland Type CR-S*F
代理商:上海颐品自动化科技有限公司
Peppers防爆格兰,Peppers防爆变径,Peppers防爆堵头,Peppers防爆呼吸阀
Peppers cable gland
Single Compression Barrier Gland featuring Peppers T-1000
Compound and a Female Conduit Connection Thread
Ex db : Ex eb : Ex nR : Ex ta : IP66 : IP68 : Class I Div 2
PRODUCT DEscriptION
“CR-S*F” type glands, used in any orientation, are certified Flameproof Ex db, Increased Safety
Ex eb, Restricted Breathing Ex nR and Dust Protected Ex ta. They are suitable for use in Group I
Mining, Zone 1 and 2 for Gas Groups IIA, IIB and IIC and additionally for use in Zones 20, 21 and
22 for Dust Groups IIIA, IIIB and IIIC. Commonly referred to as a “Conduit Stopper Box”, they are
suitable for use with conductors carried in conduit or as a line bushing for terminating flying leads.
They provide a compound barrier Ex db & IP seal on the cable inner cores, eliminating damage
to cables that exhibit “cold flow” characteristics. The unique features include Peppers T-1000, the
sealing compound that enables a quick and easy installation and an innovative barrier chamber that
allows for a full inspection of the compound fill. The gland maintains IP66 & IP68 to 100 metres and
is deluge proof without the use of an additional seal or deluge boot. It is supplied with an IP O-ring
seal as standard on metric entry threads. The gland is supplied with a female conduit connection
thread.
COMPLIANCE STANDARDS:
EN 60079-0, EN 60079-1, EN 60079-7, EN 60079-15, EN 60079-31,
IEC 60079-0, IEC 60079-1, IEC 60079-7, IEC 60079-15, IEC 60079-31 & IEC 60529
C22.2 (see certificate), CAN/CSA 60079-0/1/7, UL50
Example Part Numbering(See below for details)
CR-SBF20/NP/M20/050NPT
Materials: Brass or Stainless Steel
20 M20 x 1.5 1/2” or 3/4” 16 M20 x 1.5 1/2” or 3/4” 40 12.5 14.0 57 30.0 33.0 0.324
25 M25 x 1.5 3/4” or 1” 16 M25 x 1.5 3/4” or 1” 60 17.8 20.0 63 37.6 41.4 0.513
32 M32 x 1.5 1” or 1 ¼” 16 M32 x 1.5 1” or 1 ¼” 80 23.5 26.3 67 46.0 50.6 0.726
40 M40 x 1.5 1 ¼” or 1 ½” 16 M40 x 1.5 1 ¼” or 1 ½” 130 28.8 32.2 68 55.0 60.5 1.088
50S M50 x 1.5 1 ½” or 2” 16 M50 x 1.5 1 ½” or 2” 200 34.2 38.2 68 65.0 71.5 1.328
50 M50 x 1.5 2” 16 M50 x 1.5 2” 400 39.4 44.1 68 65.0 71.5 1.328
63S M63 x 1.5 2” or 2 ½” 19 M63 x 1.5 2” or 2 ½” 400 44.8 50.1 72 80.0 88.0 2.022
63 M63 x 1.5 2 ½” 19 M63 x 1.5 2 ½” 425 50.0 56.0 72 80.0 88.0 2.022
75S M75 x 1.5 2 ½” or 3” 19 M75 x 1.5 2 ½” or 3” 425 55.4 62.0 78 90.0 99.0 2.314
75 M75 x 1.5 3” 19 M75 x 1.5 3” 425 60.8 68.0 78 90.0 99.0 2.314
80 M80 x 2.0 3” or 3 ½” 25 M80 x 2.0 3” or 3 ½” 425 64.4 72.0 103 104.0 115.2 4.262
85 M85 x 2.0 3” or 3 ½” 25 M85 x 2.0 3” or 3 ½” 425 69.8 78.0 103 104.0 115.2 3.748
90 M90 x 2.0 3 ½” or 4” 25 M90 x 2.0 3 ½” or 4” 425 75.1 84.0 104 114.0 125.7 4.791
100 M100 x 2.0 3 ½” or 4” 25 M100 x 2.0 3 ½” or 4” 425 80.5 90.0 104 114.0 125.7 4.103
• Gland size does not necessarily equate to the entry thread size.
• UL approval/applications have a reduced core quantity. Consult product installation instructions for specific core data.
• Dimensions (A) & (B) may differ for glands with non metric entry threads. Please refer to our “Thread Reference Tables” for specific dimensions.
• Assembly instructions must be read prior to installation and adhered to in full.
• Peppers supply cable glands with parallel entry threads that conform to the flameproof threaded joint requirements of IEC/EN 60079-1 and other equivalent standards. They
usually incorporate a thread run out according to the available machining techniques and will not have a full form thread for the entire length. Peppers Cable Glands Limited will
not be held responsible for clients’ installations where this has not been taken into account.
• When selecting IP Washer & Shroud material for use with glands, please be aware of the accessories temperature range to ensure they are suitable for the intended installation.
• The gland is supplied with the correct amount of the two-part compound, gloves and instructions to allow one complete termination.
• All brass entry threads are Nickel Plated as standard.
• Where approval in addition to UL, CSA, ATEX, and IECEx is required, this must be clearly requested at time of enquiry / order.
Peppers防爆格兰,Peppers防爆变径,Peppers防爆堵头,Peppers防爆呼吸阀
Hawke防爆格兰,Hawke防爆变径,Hawke防爆堵头,Hawke防爆呼吸阀等
Feam防爆格兰,Bartec防爆变径,Feam防爆堵头,Bartec防爆呼吸阀等
Cooper防爆格兰,Cooper爆变径,Cooper防爆堵头,Cooper防爆呼吸阀等
Peppers防爆格兰及附件代理商:上海颐品自动化科技有限公司