Peppers防爆格兰(CR-U系列)
点击图片查看原图
产品: 浏览次数:0Peppers防爆格兰(CR-U系列) 
品牌: Peppers防爆呼吸阀等
单价: 面议
最小起订量: 10 只
供货总量: 500 只
发货期限: 自买家付款之日起 60 天内发货
有效期至: 长期有效
最后更新: 2023-02-02
  询价
详细信息
Peppers防爆格兰(CR-U系列)
Peppers cable gland Type CR-S*F
代理商:上海颐品自动化科技有限公司
Peppers防爆格兰,Peppers防爆变径,Peppers防爆堵头,Peppers防爆呼吸阀
Peppers cable gland
Double Compression Barrier Gland Designed for use with
Unarmoured Cable featuring Peppers T-1000 Compound
Ex db : Ex eb : Ex nR : Ex ta : IP66 : IP68 : Class I Div 2 : AEx d : AEx e : AEx ta

PRODUCT DEscriptION
“CR-U” type glands are certified Flameproof Ex db, Increased Safety Ex eb, Restricted Breathing
Ex nR and Dust Protected Ex ta. They are suitable for use in Group I Mining, Zone 1 and 2 for Gas
Groups IIA, IIB and IIC and additionally for use in Zones 20, 21 and 22 for Dust Groups IIIA, IIIB and
IIIC. Occasionally referred to as “potting glands”, they provide a compound barrier Ex db & IP seal
on the cable inner cores, eliminating damage to cables that exhibit “cold flow” characteristics and
an additional environmental seal on the outer sheath. The unique features include Peppers T-1000,
the sealing compound that enables a quick and easy installation and an innovative barrier chamber
that allows for a full inspection of the compound fill. The gland maintains IP66 & IP68 to 100 metres
and is deluge proof without the use of an additional seal or deluge boot. It is supplied with an IP
O-ring seal as standard on metric entry threads.

COMPLIANCE STANDARDS:
EN 60079-0, EN 60079-1, EN 60079-7, EN 60079-15, EN 60079-31
IEC 60079-0, IEC 60079-1, IEC 60079-7, IEC 60079-15, IEC 60079-31 & IEC 60529
C22.2 (see certificate), CAN/CSA 60079-0/1/7, UL514B, UL1203, UL2225, UL50E
ANSI/UL 60079-0/1/7, ISA 60079-31

Example Part Numbering(See below for details)
CR-UB/NP/20/M20
Materials: Brass or Stainless Steel

16 M20 x 1.5 1/2” or 3/4” 16 15 10.4 3.4 8.4 73 25.4 28.0 0.192 EL24
20S M20 x 1.5 1/2” or 3/4” 16 35 10.4 4.8 11.7 73 25.4 28.0 0.192 EL24
20 M20 x 1.5 1/2” or 3/4” 16 40 12.5 9.5 14.0 73 30.0 33.0 0.258 EL30
25 M25 x 1.5 3/4” or 1” 16 60 17.8 11.7 20.0 74 37.6 41.4 0.382 EL38
32 M32 x 1.5 1” or 1 ¼” 16 80 23.5 18.1 26.3 80 46.0 50.6 0.578 EL46
40 M40 x 1.5 1 ¼” or 1 ½” 16 130 28.8 22.6 32.2 87 55.0 60.5 0.892 EL55
50S M50 x 1.5 1 ½” or 2” 16 200 34.2 28.2 38.2 87 65.0 71.5 1.172 EL65
50 M50 x 1.5 2” 16 400 39.4 33.1 44.1 87 65.0 71.5 1.036 EL65
63S M63 x 1.5 2” or 2 ½” 19 400 44.8 39.3 50.1 88 80.0 88.0 1.726 EL80
63 M63 x 1.5 2 ½” 19 425 50.0 46.7 56.0 88 80.0 88.0 1.558 EL80
75S M75 x 1.5 2 ½” or 3” 19 425 55.4 52.3 62.0 97 90.0 99.0 1.882 EL90
75 M75 x 1.5 3” 19 425 60.8 58.0 68.0 97 90.0 99.0 1.672 EL90
80 M80 x 2.0 3” or 3 ½” 25 425 64.4 61.9 72.0 123 104.0 115.2 3.826 EL104
85 M85 x 2.0 3” or 3 ½” 25 425 69.8 69.1 78.0 123 104.0 115.2 3.238 EL104
90 M90 x 2.0 3 ½” or 4” 25 425 75.1 74.1 84.0 123 114.0 125.7 4.063 EL114
100 M100 x 2.0 3 ½” or 4” 25 425 80.5 81.8 90.0 123 114.0 125.7 3.492 EL114

• Gland size does not necessarily equate to the entry thread size.
• UL approval/applications have a reduced core quantity. Consult product installation instructions for specific core data.
• Dimensions (A) & (B) may differ for glands with non metric entry threads. Please refer to our “Thread Reference Tables” for specific dimensions.
• Assembly instructions must be read prior to installation and adhered to in full.
• Peppers supply cable glands with parallel entry threads that conform to the flameproof threaded joint requirements of IEC/EN 60079-1 and other equivalent standards. They
usually incorporate a thread run out according to the available machining techniques and will not have a full form thread for the entire length. Peppers Cable Glands Limited will
not be held responsible for clients’ installations where this has not been taken into account.
• When selecting IP Washer & Shroud material for use with glands, please be aware of the accessories temperature range to ensure they are suitable for the intended installation.
• The gland is supplied with the correct amount of the two-part compound, gloves and instructions to allow one complete termination.
• All brass entry threads are Nickel Plated as standard.
• Where approval in addition to UL, CSA, ATEX, and IECEx is required, this must be clearly requested at time of enquiry / order.