Peppers内螺纹接管式防爆格兰系列(EC*S*F)
Peppers内螺纹接管式防爆格兰系列(EC*S*F

代理商:上海颐品自动化科技有限公司
Peppers防爆格兰,Peppers防爆变径,Peppers防爆堵头,Peppers防爆呼吸阀
Peppers PRODUCT TYPE EC*S*F

Single Compression Barrier Gland featuring Peppers T2000 or T1000
Compound and a Female Conduit Connection Thread
Ex db : Ex eb : Ex nR : Ex ta : IP66 : IP68 : IP69

PRODUCT DEscriptION
"EC*-S*F" type glands, used in any orientation, are certified Flameproof Ex db, Increased Safety
Ex eb, Restricted Breathing Ex nR and Dust Protected Ex ta. They are suitable for use in Group I
Mining, Zone 1 and 2 for Gas Groups IIA, IIB and IIC and additionally for use in Zones 20, 21 and
22 for Dusts Groups IIIA, IIIB and IIIC. Commonly referred to as a "Conduit Stopper Box" they are
suitable for use with conductors carried in conduit or as a line bushing for terminating flying leads.
They provide a compound barrier Ex db & IP seal on the cable inner cores, eliminating damage
to cables that exhibit "cold flow" characteristics. The unique features include, Peppers T1000 or
T2000 compound that enables a quick and easy installation. An innovative barrier chamber that
allows for a full inspection of the compound fill. The gland maintains IP66, IP68 to 100 metres and
IP 69. Is deluge proof without the use of an additional seal or deluge boot. It is supplied with an
IP O-ring seal as standard on metric entry threads. The gland is supplied with a female conduit
connection thread.


COMPLIANCE STANDARDS:
EN 60079-0, EN 60079-1, EN 60079-7, EN 60079-15, EN 60079-31
IEC 60079-0, IEC 60079-1, IEC 60079-7, IEC 60079-15, IEC 60079-31 & IEC 60529

Example Part Numbering(See below for details)
EC2-SBF20/NP/M20/050NPT
Materials: Brass, Stainless Steel

Peppers New T2000 Compound
Hand operated No Mixing VMS Cartridge
Fast setting compound. Conductor termination can be effected from 60 minutes @ 23°C
Featuring Peppers unique “no ferrule" technology allowing it to be fully retractable and inspectable
Robust Compound for extreme conditions
Deluge proof without the requirements of additional seals or boots
Built in interface seal with metric threads

16S M16 x 1.5 3/8” 16 M16 3/8" 12 12 8.9 4.0 10.0 54.05 25.4 28.0 0.161
20 M20 x 1.5 1/2” or 3/4” 16 M20 1/2” or 3/4” 40 20 12.5 4.0 14.0 55.46 30.0 33.0 0.217
25 M25 x 1.5 3/4” or 1” 16 M25 3/4” or 1” 60 30 16.5 8.0 18.5 60.25 37.6 41.4 0.341
32 M32 x 1.5 1” or 1 ¼” 16 M32 1” or 1 ¼” 80 50 23.5 14.0 26.3 61.25 46.0 50.6 0.516
40 M40 x 1.5 1 ¼” or 1 ½” 16 M40 1 ¼” or 1 ½” 130 65 28.8 16.0 32.2 61.35 55.0 60.5 0.674
50S M50 x 1.5 1 ½” or 2” 16 M50 1 ½” or 2” 200 100 34.2 20.0 38.2 65.25 65.0 71.5 0.781
50 M50 x 1.5 2” 16 M50 2” 400 100 39.4 20.0 44.1 65.25 65.0 71.5 0.781
63S M63 x 1.5 2” or 2 ½” 19 M63 2” or 2 ½” 400 130 44.8 30.0 50.1 74.26 80.0 88.0 1.247
63 M63 x 1.5 2 ½” 19 M63 2 ½” 425 130 50.0 30.0 56.0 74.26 80.0 88.0 1.247
75S* M75 x 1.5 2 ½” or 3” 19 M75 2 ½” or 3” 425 - 55.4 - 62.0 75.75 90.0 99.0 1.339
75* M75 x 1.5 3” 19 M75 3” 425 - 60.8 - 68.0 75.75 90.0 99.0 1.339
80* M80 x 2.0 3” or 3 ½” 25 M80 3” or 3 ½” 425 - 64.4 - 72.0 92.21 104.7 115.2 3.061
85* M85 x 2.0 3” or 3 ½” 25 M85 3” or 3 ½” 425 - 69.8 - 78.0 92.35 104.7 115.2 2.512
90* M90 x 2.0 3 ½” or 4” 25 M90 3 ½” or 4” 425 - 75.1 - 84.0 89.01 114.3 125.7 3.143
100* M100 x 2.0 3 ½” or 4” 25 M100 3 ½” or 4” 425 - 80.5 - 90.0 90.01 114.3 125.7 2.603

• Gland size does not necessarily equate to the entry thread size.
• The IP O-ring seal is only available on metric entry threads. IP washers can be
supplied for tapered entry threads.
• Dimensions (A) & (B) may differ for glands with non metric entry threads.
Please refer to our “Thread Reference Tables” for specific dimensions.
• Assembly instructions must be read prior to installation and adhered to in full.
• Peppers supply products with parallel entry threads that conform to the
flameproof threaded joint requirements of IEC/EN 60079-1 and other equivalent
standards. They usually incorporate a thread run out according to the available
machining techniques and will not have a full form thread for the entire length.
Peppers Cable Glands Limited will not be held responsible for clients’ installations
where this has not been taken into account.
• When selecting IP Washer material for use with glands, please be aware of
the accessories temperature range to ensure they are suitable for the
intended installation.
• Where approval in addition to ATEX, IECEx and CSA is required, this must be
clearly requested at time of enquiry / order.

Peppers防爆格兰,Peppers防爆变径,Peppers防爆堵头,Peppers防爆呼吸阀
Hawke防爆格兰,Hawke
防爆变径,Hawke防爆堵头,Hawke防爆呼吸阀等
Feam防爆格兰,Bartec防爆变径,Feam防爆堵头,Bartec防爆呼吸阀等
Cooper防爆格兰,Cooper爆变径,Cooper防爆堵头,Cooper防爆呼吸阀等
CCG防爆格兰,CCG防爆变径,CCG防爆堵头,CCG防爆呼吸阀等
CMP防爆格兰,CMP防爆变径,CMP防爆堵头,CMP防爆呼吸阀等
Peppers防爆格兰及附件代理商:上海颐品自动化科技有限公司(EPIN)
询价单
0条  相关评论